| EtherCAT Coupler for E-bus terminals (ELxxxx) with integrated digital I/Os: – 4 digital inputs 24 V DC, filter 3.0 ms, type 3 – 4 digital outputs 24 V DC, 0.5 A, 1-wire system |
| EtherCAT Coupler for E-bus terminals (ELxxxx) with integrated digital I/Os:
– 8 digital inputs 24 V DC, filter 3.0 ms, type 3 – 4 digital outputs 24 V DC, 0.5 A, 1-wire system |
| EtherCAT Coupler for E-bus terminals (ELxxxx) with integrated digital I/Os:
– 4 digital inputs 24 V DC, filter 3.0 ms, type 3 – 8 digital outputs 24 V DC, 0.5 A, 1-wire system |
| EtherCAT Coupler for E-bus terminals (ELxxxx) with integrated digital I/Os:
– 8 digital outputs 24 V DC, 0.5 A, 1-wire system |
| EtherCAT Coupler for E-bus terminals (ELxxxx) with integrated digital standard and safety I/Os:
– 6 digital inputs, 2 of which are fail-safe inputs, 24 V DC, filter 3.0 ms, type 3 – 6 digital outputs, 2 of which are fail-safe outputs, 24 V DC, 0.5 A, 1-wire system |
| PROFIBUS Bus Coupler for EtherCAT Terminals (ELxxxx) |
| CANopen Bus Coupler for EtherCAT Terminals (ELxxxx) |
| DeviceNet Bus Coupler for EtherCAT Terminals (ELxxxx) |
| Ethernet Bus Coupler for EtherCAT Terminals (ELxxxx) |
| PROFINET RT Bus Coupler for EtherCAT Terminals (ELxxxx) |
| EtherNet/IP Bus Coupler for EtherCAT Terminals (ELxxxx) |


| mber of EtherCAT Terminals | depending on the process data size |
| Type/number of peripheral signals | depending on the process data size |
| Protocol | PROFIBUS DP |
| Data transfer rates | up to 12 Mbaud (automatic detection) |
| Configuration | not required |
| Bus interface | 1 x D-sub 9-pin socket with shielding |
| Power supply | 24 V DC (-15 %/+20 %) |
| Input current | typ. 120 mA + (total E-bus current)/4 |
| Current consumption E-bus | up to 2 A |
| Power contacts | 24 V DC max./10 A max. |
| Electrical isolation | 500 V (power contact/supply voltage/Ethernet) |
| Dimensions (W x H x D) | 64 mm x 100 mm x 73 mm |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Approvals | CE, UL, Ex |
| Accessories | |
|---|---|
| Cordsets | cordsets and connectors |
| FC310x | PC Fieldbus Cards with PCI interface |
| mber of EtherCAT Terminals | depending on the process data size |
| Type/number of peripheral signals | depending on the process data size |
| Protocol | PROFIBUS DP |
| Data transfer rates | up to 12 Mbaud (automatic detection) |
| Configuration | not required |
| Bus interface | 1 x D-sub 9-pin socket with shielding |
| Power supply | 24 V DC (-15 %/+20 %) |
| Input current | typ. 120 mA + (total E-bus current)/4 |
| Current consumption E-bus | up to 2 A |
| Power contacts | 24 V DC max./10 A max. |
| Electrical isolation | 500 V (power contact/supply voltage/Ethernet) |
| Dimensions (W x H x D) | 64 mm x 100 mm x 73 mm |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Relative humidity | 95 %, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 20/variable |
| Approvals | CE, UL, Ex |
| Accessories | |
|---|---|
| Cordsets | cordsets and connectors |
| FC310x | PC Fieldbus Cards with PCI interface |
| System |
|---|