  SKT-DR-11P美国OMEGA

  SKT-DR-11P

  过程测量和控制仪器 ? 信号调节器和发射器 ? SMLA-TC

  Thermocouple Input Field Configurable Limit Alarm

  1年保修新产品!

  Provides Relay Contact Closures at a Preset Temperature Input Level

  Field Configurable Input Ranges for Type J, K, T, E, R, and S Thermocouples

  Dynamic Deadband Prevents False Trips

  Burnout Detection

  Setpoints Programmable HI or LO

  able Failsafe/Latching Operation

  able 120/240 Vac Input Power

  产品描述

  Model SMLA-TC of field configurable limit alarms with thermocouple input offers wide ranging inputs and flexible setpoint capability. It accepts six popular thermocouple types with inputs ranging from -270°C (454°F) to 1760°C (3200°F). The SMLA-TC provides two independent setpoint alarms (2 SPDT, 5A) and includes 0.25% to 50% adjustable deadbands and able 120/240 Vac power.

  Model SMLA-TC is equipped with a dual function diagnostic LED. The green center LED indicates line power and input signal status. Active line power is indicated by an illuminated LED. If the center LED is off, check line power and the wiring connection. If the input signal is above full scale, the LED will flash at approximately 8 Hz. Below 0%, the flash rate is approximately 4 Hz.

  Setpoints are top accessed multi-turn potentiometers. The field configurable SMLA-TC limit alarm setpoints can be configured for HI, LO, latching or fail-safe trip operation. Non-latching HI and LO setpoints have respective HI and LO deadbands. In a tripped condition, the setpoint is exceeded and the appropriate red LED is lit. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband. To reset a latched setpoint the signal must be in the safe region and the line power must be turned off for at least 5 seconds. For proper deadband operation, the HI setpoint must always be set above the LO setpoint.

  In failsafe operation, the relay is energized when the process is below a HI setpoint or above a LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm condition.

  The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This effectively results in a “dynamic deadband” - based on time - in addition to the normal deadband.

  The factory default configuration for the SMLA-TC is as follows:

  Input: Type J, 0 to 360°C (32 to 680°F)

  Burn Out: Positive

  Output: Dual, SPDT

  Trip: A: HI, B: LO

  Latching: No

  Failsafe: No

  Deadband: A/B: 0.25%

  Power: 120 Vac

  When switching inductive loads, maximum relay life and transient EMI suppression is achieved using external protection. Place all protection devices directly across the load and minimize lead lengths. For AC inductive loads, place a properly rated MOV across the load in parallel with a series RC snubber. Use a 0.01 to 0.1 mF pulse film capacitor (foil polypropylene recommended) of sufficient voltage, and a 47 Ω, ? W carbon resistor. For DC inductive loads, place a diode across the load (PRV gt; DC supply, 1N4006 recommended) with (+) to cathode and (-) to anode (the RC snubber is an optional enhancement).

  Specifications

  INPUT

  Ranges: Field configurable, see table

  Impedance: gt;1 MΩ

  Input Bias Current (Burnout Detect): lt;1.5 μA

  Overvoltage: ±10 V differential

  Common Mode (Input to Ground): 600 Vac or 1000 Vdc max

  LED Indications:

  Input Range (Green);

  gt; Input: 8 Hz flash

  lt;0% Input: 4 Hz flash

  Setpoint (Red): Tripped; Solid red (one LED for each setpoint)

  Limit Differential (Deadband): 0.25% to 50% of span

  Response Time:

  Dynamic Deadband: Relay status will change when proper setpoint/process condition exists uninterrupted

  for 100 msec

  Normal Mode (Analog Filtering): lt;250 msec (10 to 90%)

  Setpoint:

  Effectivity: Setpoints are adjustable over of input span

  Repeatability (Constant Temp): ±0.2% for inputs gt; 0°C; ±0.3% for inputs lt; 0°C

  Stability:

  Line Voltage: ±0.01%/% max

  Temperature: ±0.05% of full scale/°C max

  Common Mode Rejection (DC to 60 Hz): 120 dB

  Isolation: 1000 Vdc between contacts, input and power

  ESD Susceptibility: Meets IEC 801-2, Level 2 (4 KV)

  Humidity:

  Operating: 15 to 95% RH @ 45°C (113°F)

  Soak: 90% RH for 24 hours @ 65°C (149°F)

  Temperature Range:

  Operating: 0 to 60°C (32 to 140°F)

  Storage: -15 to 70°C (5 to 158°F)

  Power: 120/240 Vac ± 10%, 50 to 60 Hz able, 2 W typical, 5 W max

  Relay Contacts: 1 SPDT (1 Form C) per setpoint

  Current Rating (Resistive):

  120 Vac: 5A

  240 Vac: 2A

  28 Vdc: 5A

  Material: Silver-Cadmium Oxide

  Electrical Life: 105 operations at rated load (external relay contact protection is required for use with inductive loads)

  Mechanical Life: 107 operations

  Latch Reset Time: 5 seconds (with power removed)

  Weight: 291 g (0.64 lb)

  产品编号 产品描述

  SMLA-TC Thermocouple input field configurable limit alarm

  Accessories

  SKT-DR-11P 11-pin socket, DIN rail mount

  SKT-SM-11P 11-pin socket, surface mount

  SM-RAIL-2 35 mm DIN rail, 2 m (6.6') length

  SMRS Retaining spring (secures limit alarm module into DIN rail or surface mount socket)

  产品编号