OM-USB-2404-UI数据采集器 美国OMEGA进口OM-USB-2404-UI
OM-USB-2404-UI
USB, RS232, RS485和Ethernet数据采集... ? OM-USB-2404-UI
4-Channel Universal Analog Input USB Data Acquisition Module
OM-USB-2404-UI
4 Channels of Universal Analog Input
24-Bit Resolution
Measures: Voltage (±125 mV, ±1V, ±4V, ±15V, ±60V), Current (±25 mA), Thermocouples (J, K, T, E, R, S, N, B), RTDs (Pt100, Pt1000, 3- and 4-Wire), Resistance (2- and 4-Wire), and Bridge-Based Sensors (Quarter-, Half-, and Full-Bridge)
Simultaneous Sampling at Up to 100 S/s Per Channel
250 Vrms Channel-to-Channel and Channel-to-Ground Isolation
Built-In Thermistor for Cold-Junction Compensation (CJC)
Six-Position Input Screw Terminal Allows Different Measurement Types to be Performed On Each Channel
产品描述
The new OM-USB-2404-UI provides four channels of 24-bit universal analog input with integrated signal conditioning. The device can be used to measure a variety of sensor types such as RTDs, thermocouples, load cells, and other powered sensors. The four channels are individually configurable, so a different measurement type can be performed on each channel. All channels are measured simultaneously at up to 100 S/s per channel.
The OM-USB-2404-UI can perform the following measurements: ? Voltage ? Current ? Thermocouple ? RTD (3- and 4-wire) ? Resistance (2- and 4-wire) ? Bridge-based sensors (quarter-, half-, and full-bridge) Measurement ranges vary for each type of measurement (see PDF for complete specifications).
The device features a built-in current and voltage excitation. The excitation circuit is protected from overcurrent and overvoltage fault conditions. Each channel also has a built-in thermistor for cold-junction compensation (CJC) calculations when measuring thermocouples. An analog pre-filter removes noise that may be present in the signals prior to conversion.
With 250 Vac channel-to-channel and channel-to-ground isolation, the OM-USB-2404-UI protects the individual channels and connected computer and ensures a reliable data stream. Each channel has a detachable six-position screw terminal block for field wiring connections.
The OM-USB-2404-UI ships with a 2 m (6') USB cable and is powered by the 5V USB supply from your computer. No external power is required.
The OM-USB-2404-UI is a USB 2.0 high-speed device that is supported under popular Microsoft Windows? operating systems. The OM-USB-2404-UI is fully compatible with both USB 1.1 and USB 2.0 ports.
Software The OM-USB-2404-UI module ships with an impressive array of software, including the new TracerDAQ?, a full-featured, out-of-the-box data logging, viewing, and analysis application. Driver support and detailed example programs are included for Universal Library programming libraries for Microsoft? Visual Studio? programming languages, and other languages, including DASYLab?, and ULx for NI LabVIEW? (comprehensive library of Vls and example programs compatible with 32-bit and 64-bit LabVIEW v8.5 through 2013) and InstaCal? installation, calibration and test utility-powerful solutions for programmers and nonprogrammers alike. These modules operate under Microsoft Windows? XP (32-bit only) and VISTA/7/8 (32-bit and 64-bit) operating systems.
The OM-USB-2404-UI data acquisition module is supplied with TracerDAQ software which is a collection of four virtual instrument applications used to graphically display and store input data and generate output signals:
? Strip Chart—Log and graph values acquired from analog inputs, digital inputs, temperature inputs and counter inputs
? Oscilloscope—Display values acquired from analog inputs
? Function Generator—Generate waveforms for analog outputs
? Rate Generator—Generate waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ. A comparison of some of the features included in TracerDAQ vs TracerDAQ PRO is shown on the PDF.
SPECIFICATIONS
ANALOG INPUT
Number of Channels: 4
A/D Converter Resolution: 24-bit
A/D Converter Type: Delta-Sigma with analog pre-filtering
Sampling Mode: Simultaneous
TEDS Sensor Type Supported: IEEE 1451.4 TEDS Class II (interface)
Input Mode: Voltage, current, resistance (2- and 4-wire), RTD (3- and 4-wire), thermocouple, quarter-bridge, half-bridge, full-bridge
Conversion Time (No channels in TC mode)
High Speed: 10 ms for all channels
Best 60 Hz Rejection: 110 ms for all channels
Best 50 Hz Rejection: 130 ms for all channels
High Resolution: 500 ms for all channels
Conversion Time (One or More Channels in TC Mode)
High Speed: 20 ms for all channels
Best 60 Hz Rejection: 120 ms for all channels
Best 50 Hz Rejection: 140 ms for all channels
High Resolution: 510 ms for all channels
Overvoltage Protection
Terminals 1 and 2: ±30V
Terminals 3 Through 6, Across any Combination: ±60V
Input Impedance
Voltage Mode (±60V, ±15V, ±4V): 1 MΩ
Current Mode: <40 Ω
All Other Modes: >1GΩ
Input Bias Current: <1nA
Integral Non-Linearity (INL): ±15 ppm
Common Mode Rejection Ratio (CMRR): >100 dB
Normal Mode Rejection Ratio (NMRR)
Best 60 Hz Rejection: 90 dB at 60 Hz
Best 50 Hz Rejection: 80 dB at 50 Hz
High Resolution: 65 dB at 50 Hz and 60 Hz
GENERAL
Operating Temperature Range: 0 to 60oC (32 to 140oF), 10 to 90% RH non-condensing
Storage Temperature Range: -40 to 85oC (-40 to 185oF), 5 to 95% RH non-condensing
Communications: USB 2.0 Hi-Speed mode (480 Mbps) is recommended; otherwise USB 1.1 full-speed mode (12 Mbps)
Current Consumption from USB: 500 mA, maximum
Channel-to-Earth Ground Isolation
Continuous: 250 Vrms (measurement category II for measurements performed on circuits directly
connected to the electrical distribution system)
Withstand: 2300 Vrms (verified by a 5 second dielectric withstand test)
Channel-to-Channel Isolation
Continuous: 250 Vrms (measurement category II for measurements performed on circuits directly
connected to the electrical distribution system)
Withstand: 1390 Vrms (verified by a 5 second dielectric withstand test)
Signal I/O Connector: 6-position screw terminals
Screw terminal Wiring: 18 to 28 AWG copper conductor wire with 7 mm (0.28") of insulation stripped from the end
Maximum Altitude: 2000 m (6562')
Dimensions: 134 L x 143 W x 39 mm H (5.27 x 5.64 x 1.54")
Weight: 567 g (1.25 lb)
产品编号 产品描述
OM-USB-2404-UI 4-channel universal analog input USB data acquisition module
Accessories
OM-ACC-164 Spare 6-position screw terminal connectors for the OM-USB-2404-UI (quantity of 4)
OM-ACC-176 Backshell kit for use with the OM-ACC-164, 6-position connectors (quantity of 4)
SWD-TRACERDAQ-PRO TracerDAQ PRO software
产品型号
OM-USB-1208FS
OM-USB-1208HS
OM-USB-1208HS-2AO
OM-USB-1208HS-4AO
OM-USB-1408FS
OM-USB-1608FS
OM-USB-1608FS-PLUS
OM-USB-1608G
OM-USB-1608GX
OM-USB-1608GX-2AO
OM-USB-2404-10
OM-USB-2404-60
OM-USB-2404-UI
OM-USB-3101
OM-USB-3103
OM-USB-3105
OM-USB-32DIO
OM-USB-5200-ADAPTOR
OM-USB-5201
OM-USB-5203
OM-USB-QUAD08
OM-USB-TC
OM-USB-TC-AI
OM-USB-TC-NIST
OM-USB-TEMP
OM-USB-TEMP-AI
产品型号
SWD-480-AS
SWD-ANTI
SWD-CEG-1
SWD-CHDRAW
SWD-COLLECT
SWD-COLLECT/W-3.5
SWD-COLLECT/WIN95
SWD-CWOPT232S2
SWD-CWOPT485S
SWD-DASWIZARD
SWD-DASYLAB
SWD-DASYLAB-FULL
SWD-DASYLAB-PRO
SWD-DASYLAB-RT
SWD-DASYLITE
SWD-LTC-WIN95
SWD-LTNPRO-WIN95
SWD-MESSENGERWARE-LITE
SWD-MID
SWD-TRACERDAQ-PRO
SWD-PRONTO-WIN
SWD-WBWIN-LITE
SWD-WINWEDGE32
SWD-WINWEDGE32-PRO
OM-ACC-102
OM-ACC-160
OM-ACC-164
OM-ACC-176
OM-USB-2404-UI
OM-USB-2404-UI数据采集器 美国OMEGA进口OM-USB-2