DPU91美国OMEGA

DPU91美国OMEGA

价格 面议
起订量 10㎡
货源所属商家已经过真实性核验
品牌 美国OMEGA
型号 DPU91
关键字
在线咨询 立即下单 留言询价 电话咨询
深圳市鑫博恒业科技有限公司
通过真实性核验手机验证
主营:
美国omega热电偶

进入店铺全部产品

店内推荐

联系我们

联系人:赵先华

邮箱:235521054@qq.com

电话:13823144468

地址: 广东深圳市深圳市福田区华强北路华强广场A栋17A

产品详情

  DPU91美国OMEGA

  DPU91

  

  指示器,累加器,批量控制器和信号调节器 DPU91_FLOW

  Multi-Parameter Input Transmitter

  DPU91_FLOW

  Large Auto-Sensing Backlit Display

  “Dial-Style” Digital Bar Graph

  Intuitive and “User-Friendly” Interface

  Optional Field Upgradable Relays

  Warning LED Indicator

  Custom 13-Character Label Capabilities

  Factory Reset CapabilityT

  产品描述

  The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH/ORP, conductivity/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90") autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a “dial-style” digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

  Specifications

  General

  Input Channels: 1

  Input Types: Digital serial ASCII, TTL level, 9600 bps

  Frequency Range: 0.5 to 1500 Hz

  Accuracy: 0.5% of reading (display)

  Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch

  Enclosure and Display

  Case Material: PBT

  Window: Shatter-resistant glass

  Keypad: 4 buts, injection-molded silicone rubber seal

  Display: Backlit, 7 and 14-segment

  Rate: 1 second

  LCD Contrast: 5 settings

  Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator

  Enclosure: DIN, NEMA 4X/IP65

  Mounting Panel: DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)

  Field Mounts: Specified to Omega field mount junction boxes

  Weight: 0.63 kg (1.63 lb) DPU91-FLOW Series

  Display Ranges For conductivity/resistivity version visit For pH/ORP version visit dpu91_ph

  Flow Rate: -9999 to 99999 units per second, minute, hour or day

  Totalizer: 0.00 to 99999999 units (program lockout or resettable)

  Temperature: -99 to 350°C (-146 to 662°F)

  Volume: 0 to 99999 cm3, m3, in3, ft3, gal, L, lb, kg, %

  Environmental

  Ambient Operating Temperature:

  Backlit LCD: -10 to 70°C (14 to 158°F)

  Storage Temperature: -15 to 70°C (5 to 158°F)

  Relative Humidity: 0 to condensing for field mount; 0 to 95% non-condensing for panel mount

  Maximum Altitude: 4000 m (13,123')

  Electrical Requirements

  Power to Sensors:

  Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected

  Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge

  Input Power

  DC: 10.8 to 35.2 Vdc, regulated

  Current Output:

  4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)

  DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc

  DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc

  Open Collector: 1

  Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection

  Relay Specifications (DPU90-R optional)

  Type: SPDT, Form C

  Maximum Current Rating: 5 A resistive 50 mA DC

  Maximum Voltage Rating: 30 Vdc or 250 Vac

  Hysteresis Adjustable: Absolute in engineering units (EUs)

  Latch Reset: In test screen only

  Delay: 9999.9 seconds (maximum)

  Test Mode: Set on/off

  Cycle Time: 99999 seconds (maximum)

  Maximum Pulse Rate: 400 pulses/minute

  Proportional Pulse: 400 pulses/minute

  Volumetric Pulse Width: 0.1 to 3200 s

  Pulse Width Modulation: 0.1 to 320 s

  Input Types

  Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics (For pH models see dpu91_ph)

  Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 (For conductivity/resistivity models see dpu91_conductivity)

  Input Specifications

  Digital Serial: ACSII, TTL level, 9600 bps

  Frequency Input:

  Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency

  Span: 0.5 Hz to 1500 Hz @ TTL level input

  Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)

  Repeatability: ±0.2% of reading

  注: DPU91 and DPU91P come complete with operator’s manual.

  产品编号 产品描述

  DPU91 DC powered field mount multi-parameter display and transmitter (Requires FP90UM mounting kit)

  DPU91P DC powered panel mount multi-parameter display and transmitter

  DPU91-BC DC powered flow display and transmitter with batch control

  Accessories

  DPU90-AK Angle adjustment kit for field mount

  DPU90-BCM Batch controller module

  DPU90-COMM Communications module, HART protocol super imposes digital signal

  DPU90-CT PC configuration took, includes software

  DPU90-R programmable dual relay output module, SPDT form C, 5A resistive load

  DPU90-WM Wall mount accessory kit

  FP90UM Universal mounting bracket for field mounted units

  FP90IM Integral mount kit for use with FP8500 series paddlewheels

  FPM-5000-LTCK Liquid tight connector kit for wiring feed through

  DPU91

  DPU91美国OMEGA

  

  DPU91美国OMEGA 新相关产品:PHEH-276G美国OMEGA

  

售后服务

商家电话:
13823144468