  DPG1000ADA-2000KPAG-1N Omega压力仪表DPG1000ADA-2000KPAG-1N

  DPG1000ADA-20.00KPAG-1N

  报装置和模拟输出功能的数字压力计

  DPG1000ADA_DPG1000DAR系列

  DPG1000ADA_DPG1000DAR 系列:报装置和模拟输出功能的数字压力计

  DPG1000ADA-15G-1N

  AD or DC Powered with Dual Alarms

  DC Powered with Dual Alarms and Analog Output

  Ranges between 15 psi and 3000 psi

  Normal or Reverse Acting Alarms

  Hi/Lo, Hi/Hi, or Lo/Lo Alarms available

  Colored LED Alarm Status Indicators

  Using the DPG1000ADA and DPG1000DAR Alarm Outputs Normal (Fail-safe) vs. Reverse Action—The convention for alarm action is that with the normal or fail-safe configuration, the alarm output relays will be CLOSED (relay energized) for a clear or non-alarm condition and OPEN (relay not energized) for an alarm condition. This is primarily for users who require an alarm condition if the gauge loses power or suffers a catastrophic failure. In the wiring diagrams, the normally closed and normally open designations refer to standard relay terminology (i.e., the relay contact status with the relay coil not energized). Therefore, with the normal (fail-safe) configuration in a green or non-alarm condition, the relay will be energized so that continuity can be expected between the common and normally open leads. In a red or alarm condition, the relay will be open (not energized) so that continuity can be expected between the common and normally closed leads.

  Contact Rating and Protection The contacts of the alarm relays are rated at 1 A/24 Vdc or 0.5 A/ 115 Vac. Switching loads greater than the rating, or switching large inductive loads, will shorten the useful life of the contacts. In lowlevel switching or with dry contacts, the user should consider whether external contact protection, such as snubber networks or arc suppression networks, is required to protect the contacts. In addition, no internal fusing is included in the DPG1000 contact circuits. The circuit external to the gauge alarm outputs should be fused by the user in applications in which good design dictates this practice.

  Using the DPG1000DAR Analog Output The analog output is easy to use if a few system considerations are observed. The DPG1000DAR is DC powered, with the gauge power supply (–) tied to the 4 to 20 mA (–). Therefore, the DC supply (–) lead should be considered common with regard to the analog output (–) or ground connection in the user’s system. Be sure to observe the output compliance (voltage drive) capabilities of the gauge. The compliance, and therefore the maximum loop resistance the output can drive, is a function of the supply voltage to the gauge. Consult the manual for maximum loop resistance vs. supply voltage. Too large a loop resistance will cause the gauge output to “limit” or saturate before reaching its full 20 mA output.

  DPG1000ADA AC/DC Powered with Dual Alarms

  SPECIFICATIONS

  Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)

  Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to range; top-accessible, multiturn potentiometers

  Alarm Deadbands (Hysteresis): 1% of FSO, standard

  Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive

  Alarm Indicators: Bicolor (red/green) LEDs on front panel

  Test Function: Front-panel TEST but, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation

  Alarm Response Time: 100 ms typical

  Power: Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS)

  DPG1000DAR DC Powered with Dual Alarms and 4 to 20 mA Output

  SPECIFICATIONS

  Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)

  Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to range; test calibration level, 0 to range; top-accessible, multiturn potentiometers analog output zero/span; internal potentiometers

  Alarm Deadbands (Hysteresis): 1% of FSO, standard

  Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive

  Alarm Indicators: Bi-color (red/green) LEDs on front panel

  Alarm Response Time: 100 ms typical

  Analog Output: 4 to 20 mA DC; output drive (compliance) determined by power source

  Analog Output Response Time: 50 ms, typical

  Test Function: Front-panel TEST but, when depressed, toggles both SP1 and SP2 alarm status and simultaneously sets display and analog output to “calibration” level, independent of pressure input, to allow testing system operation

  Power: Any DC source of 9 to 32 Vdc, 1.0 W max

  Electrical Connection: 0.9 m (3') long, 4-conductor 22 AWG shielded cable for power and retransmitted output; 0.9 m (3') long, 6-conductor 22 AWG cable for alarm contacts

  ALARMS (final siffix 1N standard)

  1 = HI/LO (standard)

  2= HI/HI

  3= LO/LO

  N = Normal Acting (standard)

  R = Reverse Acting

  Example: DPG1000ANA-15G-3R HAS LO/LO ALARMS, Reverse Acting

  nbsp;DPG1000ADA-20.00KPAG-1Nnbsp;