产品详情
型号

进口锂电池供电电磁流量计

测量范围

O<p<5g/cm3

准确度

±1~2.5%

加工定制

产地

美国

厂家

RETZ

  品牌:RETZ瑞茨/我们一直致力于流体控制和测控领域的持续创新,始于2005……

  进口锂电池供电电磁流量计原理及用途Principleand purpose

  1.电池供电电磁流量计由传感器和转换器两部分构成。它是基于法拉第电磁感应定律工作的,用来测量电导率大于5μS/cm导电液体的体积流量,是一种测量导电介质体积流量的感应式仪表。除可测量一般导电液体的体积流量外,还可用于测量强酸强碱等强腐蚀液体和泥浆、矿浆、纸浆等均匀的液固两相悬浮液体的体积流量retz Thebattery powered electromagnetic flowmeter consists of a sensor and a converter.It is based on Faraday's law of electromagnetic induction and is used tomeasure electrical conductivity greater than 5 μ The volume flow rate of S/cmconductive liquid is an inductive instrument for measuring the volume flow rateof conductive media. In addition to measuring the volume flow rate of generalconductive liquids, it can also be used to measure the volume flow rate ofstrong corrosive liquids such as strong acids and alkalis, and homogeneousliquid-solid two-phase suspension liquids such as mud, pulp, and pulp

  2.基本原理(如图所示)基于法拉第电磁感应定律:E=K*B*D*V,其中E是感应电动势;K是仪表常数;B是磁感应强度;D是测量管直径;V是平均流速 The basicprinciple (as shown in the figure) is based on Faraday's law of electromagneticinduction: E=K * B * D * V, where E is the induced electromotive force; K isthe meter constant; B is the magnetic induction strength; D is the diameter ofthe measuring tube; V is the average flow rate

  (1)只能测量导电介质 Only conductivemedia can be measured

  电导率限制条件6≥1-5uS/cm(水>20uS/cm)(低电导率>0.05uS/cm使用专用仪表) Conductivitylimit condition 6 ≥ 1-5uS/cm (water>20uS/cm) (low conductivity>0.05uS/cmusing dedicated instruments)原理及用途.jpg

  不能测量非导电介质,如气体,油类,如介质含有大量气体,产生测量严重波动Unable to measure non-conductive media such as gases and oils, such as mediacontaining a large amount of gas, resulting in severe fluctuations inmeasurement

  (2)必须存在磁场 Magnetic fieldmust be present

  励磁电流流经测量管上下励磁线圈产生磁场。励磁线圈断路,流量计不工作,励磁电流稳定性直接影响仪表测量 Theexcitation current flows through the upper and lower excitation coils of themeasuring tube to generate a magnetic field. The excitation coil is opencircuit, the flowmeter does not work, and the stability of the excitationcurrent directly affects the instrument measurement

  测量管必须为非导磁材料,保证磁场穿过导管(测量管应采用不锈钢材质) The measuringtube must be made of non magnetic conductive material to ensure that themagnetic field passes through the tube (the measuring tube should be made ofstainless steel)

  (3)实际测量值为流体流速 The actualmeasured value is the fluid flow rate

  电磁流量计实际测量介质的流速(它是速度式流量计) Electromagneticflowmeter actually measures the flow rate of the medium (it is a velocity typeflowmeter)

  进口锂电池供电电磁流量计技术参数Technical parameter

  公称通径(mm)

  (特殊规格可定制) 管道式:DN10~DN3000

  插入式:DN200~DN3000

  流动方向: 正,反,净流量

  量程比: 150:1

  重复性误差: 测量值的±0.1%

  精度等级: 管道式:0.5级,1.0级

  被测介质温度: 普通橡胶衬里:-20~+60℃

  高温橡胶衬里:-20~+90℃

  聚四氟乙稀衬里:-30~+100℃

  高温型四氟衬里:-20~+180℃

  额定工作压力:

  (高压可定制) DN6-DN80:≤1.6MPa

  DN100-DN250:≤1.0MPa

  DN300-DN1200:≤0.6MPa

  流速范围: 0.1-15m/s

  电导率范围: 被测流体电导率≥5μs/cm

  电流输出: 负载电阻 0~10mA:0~1.5kΩ

  4~20mA:0~750 kΩ

  数字频率输出: 输出频率上限可在1~5000HZ内设定带光电隔离的晶体管集电极开路双向输出。外接电源≤35V导通时集电极*大电流为250mA

  供电电源: AC220V、DC24V或3.6V电池

  要求直管段长度 上游≥5DN,下游≥2DN

  连接方式: 流量计与配管之间均采用法兰连接,法兰连接尺寸应符合GB11988的规定

  防爆等级: mdIIBT4

  防护等级: IP65,特殊订制*高可达IP68

  环境温度: -25~+60℃

  相对温度: 5%~95%

  消耗总功率: 小于20W